Description: CTR,3P,80A,100-250VAC/DC,2/2
CUP: 3471523133037
Descripteurs
|
Catégorie |
AF Contactors |
|
Block Contactor Type |
3-Pole Contactor |
Spécifications
|
Product Type |
AF |
|
General Use Rating UL/CSA |
(600 V AC) 105 A |
|
Object Classification Code |
Q |
|
Terminal Type |
Screw Terminals |
|
Rated Control Circuit Voltage |
50 Hz /60 Hz DC Operation 100 ... 250 V |
|
Number of Main Contacts NO |
3 |
|
Number of Main Contacts NC |
0 |
|
Climatic Withstand |
Category B according to IEC 60947-1 Annex Q |
|
Resistance to Vibrations acc. to IEC 60068-2-6 |
5 ... 300 Hz 3 g closed position / 3 g open position |
|
Number of Auxiliary Contacts NO |
1 |
|
RoHS Status |
Following EU Directive 2011/65/EU |
|
Reference Ambient Air Temperature |
Close to Contactor for Storage -60 ... +80 °C |
|
Rated Operational Voltage |
Auxiliary Circuit 690 V |
|
Resistance to Shock acc. to IEC 60068-2-27 |
Closed, Shock Direction: A 25 K40 |
|
Number of Auxiliary Contacts NC |
1 |
|
Tightening Torque UL/CSA |
Auxiliary Circuit 11 IA |
|
Maximum Operating Altitude Permissible |
3000 m |
|
Rated Operational Current AC-1 |
(690 V) 40 °C 125 A |
|
Rated Operational Power AC-3 |
(220 / 230 / 240 V) 22 KWT |
|
Horsepower Rating UL/CSA |
(220 ... 240 V AC) Three Phase 30 hp |
|
Conventional Free-air Thermal Current |
acc. to IEC 60947-5-1, q = 40 °C 16 A |
|
Rated Operational Current AC-15 |
(220 / 240 V) 4 A |
|
Rated Frequency |
Auxiliary Circuit 50 Hz |
|
Rated Short-time Withstand Current |
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 780 A |
|
Rated Operational Current AC-3 |
(220 / 230 / 240 V) 60 °C 80 A |
|
Maximum Electrical Switching Frequency |
AC-1 600 cycles per hour |
|
Rated Insulation Voltage |
acc. to UL/CSA 600 V |
|
Maximum Breaking Capacity |
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A |
|
Maximum Mechanical Switching Frequency |
3600 cycles per hour |
|
Operate Time |
Between Coil De-energization and NC Contact Closing 19 ... 105 ms |
|
Secondary Rated Impulse Withstand Voltage |
8 kV |
|
Connecting Capacity Main Circuit |
Rigid 1x 6 ... 70 m²/2x 6 ... 50 m² / |
|
Rated Operational Current DC-13 |
(125 V) 0.55 A / 69 W |
|
Connecting Capacity Control Circuit |
Flexible with Ferrule 1/2x 0.75 ... 2.5 m² |
|
Degree of Protection |
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 |
|
Connecting Capacity Auxiliary Circuit |
Flexible with Ferrule 1/2x 0.75 ... 2.5 m² |
|
Screw Terminal Type |
Screw Terminals |
|
Wire Stripping Length |
Main Circuit 17 mm |
Classifications
|
ETIM 4 |
EC000066 - Magnet contactor, AC-switching |
|
ETIM 6.0 |
EC000066 - Power contactor, AC switching |
|
ETIM 7 |
EC000066 - Power contactor, AC switching |
|
ETIM 5.0 |
EC000066 - Magnet contactor, AC-switching |
Dimensions
|
Product Net Weight |
1.21 kg |
|
Product Net Depth / Length |
116 mm |
|
Product Net Width |
82 mm |
|
Product Net Height |
125.5 mm |
Package Information
|
Package Level 1 Width |
150 mm |
|
Package Level 1 Height |
103 mm |
|
Package Level 1 Depth / Length |
150 mm |
|
Package Level 1 EAN |
3471523133037 |
|
Package Level 1 Units |
box 1 piece |
|
Package Level 2 Width |
250 mm |
|
Package Level 2 Height |
300 mm |
|
Package Level 1 Gross Weight |
1.33 kg |
|
Package Level 2 Units |
box 8 piece |
|
Package Level 3 Units |
192 piece |
|
Package Level 2 Depth / Length |
300 mm |
|
Package Level 2 Gross Weight |
10.64 kg |
Ordering
|
Minimum Order Quantity |
1 |
|
Customs Tariff Number |
85364900 |